2024-12-18thermal/thresholds: Fix boundaries and detection routineDaniel Lezcano
The current implementation does not work if the thermal zone is interrupt driven only. The boundaries are not correctly checked and computed as it happens only when the temperature is increasing or decreasing. The problem arises because the routine to detect when we cross a threshold is correlated with the computation of the boundaries. We assume we have to recompute the boundaries when a threshold is crossed but actually we should do that even if the it is not the case. Mixing the boundaries computation and the threshold detection for the sake of optimizing the routine is much more complex as it appears intuitively and prone to errors. This fix separates the boundaries computation and the threshold crossing detection into different routines. The result is a code much more simple to understand, thus easier to maintain. The drawback is we browse the thresholds list several time but we can consider that as neglictible because that happens when the temperature is updated. There are certainly some aeras to improve in the temperature update routine but it would be not adequate as this change aims to fix the thresholds for v6.13. Fixes: 445936f9e258 ("thermal: core: Add user thresholds support") Tested-by: Daniel Lezcano <daniel.lezcano@linaro.org> # rock5b, Lenovo x13s Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20241216212644.1145122-1-daniel.lezcano@linaro.org Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-10-24thermal: thresholds: Fix thermal lock annotation issueDaniel Lezcano
When the thermal zone is unregistered (thermal sensor module being unloaded), no lock is held when flushing the thresholds. That results in a WARN when the lockdep validation is set in the kernel config. This has been reported by syzbot. As the thermal zone is in the process of being destroyed, there is no need to send a notification about purging the thresholds to the userspace as this one will receive a thermal zone deletion notification which imply the deletion of all the associated resources like the trip points or the user thresholds. Split the function thermal_thresholds_flush() into a lockless one without notification and its call with the lock annotation followed with the thresholds flushing notification. Please note this scenario is unlikely to happen, as the sensor drivers are usually compiled-in in order to have the thermal framework to be able to kick in at boot time if needed. Fixes: 445936f9e258 ("thermal: core: Add user thresholds support") Link: https://lore.kernel.org/all/67124175.050a0220.10f4f4.0012.GAE@google.com Reported-by: syzbot+f24dd060c1911fe54c85@syzkaller.appspotmail.com Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20241024102303.1086147-1-daniel.lezcano@linaro.org [ rjw: Subject edit, added Fixes tag ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-10-24thermal: netlink: Add the commands and the events for the thresholdsDaniel Lezcano
The thresholds exist but there is no notification neither action code related to them yet. These changes implement the netlink for the notifications when the thresholds are crossed, added, deleted or flushed as well as the commands which allows to get the list of the thresholds, flush them, add and delete. Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Link: https://patch.msgid.link/20241022155147.463475-3-daniel.lezcano@linaro.org [ rjw: Use the thermal_zone guard for locking, subject edit ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-10-10thermal: core: Add user thresholds supportDaniel Lezcano
The user thresholds mechanism is a way to have the userspace to tell the thermal framework to send a notification when a temperature limit is crossed. There is no id, no hysteresis, just the temperature and the direction of the limit crossing. That means we can be notified when a threshold is crossed the way up only, or the way down only or both ways. That allows to create hysteresis values if it is needed. A threshold can be added, deleted or flushed. The latter means all thresholds belonging to a thermal zone will be deleted. When a threshold is added: - if the same threshold (temperature and direction) exists, an error is returned - if a threshold is specified with the same temperature but a different direction, the specified direction is added - if there is no threshold with the same temperature then it is created When a threshold is deleted: - if the same threshold (temperature and direction) exists, it is deleted - if a threshold is specified with the same temperature but a different direction, the specified direction is removed - if there is no threshold with the same temperature, then an error is returned When the threshold are flushed: - All thresholds related to a thermal zone are deleted When a threshold is crossed: - the userspace does not need to know which threshold(s) have been crossed, it will be notified with the current temperature and the previous temperature - if multiple thresholds have been crossed between two updates only one notification will be send to the userspace, it is pointless to send a notification per thresholds crossed as the userspace can handle that easily when it has the temperature delta information Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20240923100005.2532430-2-daniel.lezcano@linaro.org [ rjw: Subject edit, use BIT(0) and BIT(1) in symbol definitions ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>