summaryrefslogtreecommitdiff
path: root/drivers/iio/adc/ad_sigma_delta.c
AgeCommit message (Collapse)Author
2025-07-16iio: adc: ad_sigma_delta: change to buffer predisableDavid Lechner
Change the buffer disable callback from postdisable to predisable. This balances the existing posteanble callback. Using postdisable with posteanble can be problematic, for example, if update_scan_mode fails, it would call postdisable without ever having called posteanble, so the drivers using this would be in an unexpected state when postdisable was called. Fixes: af3008485ea0 ("iio:adc: Add common code for ADI Sigma Delta devices") Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250703-iio-adc-ad_sigma_delta-buffer-predisable-v1-1-f2ab85138f1f@baylibre.com Cc: <stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: add SPI offload supportDavid Lechner
Add SPI offload support to the ad_sigma_delta module. When the SPI controller has SPI offload capabilities, the module will now use that for buffered reads instead of the RDY interrupt trigger. Drivers that use the ad_sigma_delta module will have to opt into this by setting supports_spi_offload since each driver will likely need additional changes before SPI offload can be used. This will allow us to gradually enable SPI offload support for each driver. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-11-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: use spi_optimize_message()David Lechner
Use spi_optimize_message() to improve the performance of buffered reads. By setting up the SPI message and pre-optimizing it in the buffer postenable callback, we can reduce overhead during each sample read. A rough estimate shows that this reduced the CPU usage of the interrupt handler thread from 22% to 16% using an EVAL-AD4112ARDZ board on a DE10-Nano (measuring a single channel at the default 6.2 kHz sample rate). Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-8-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: refactor setting read addressDavid Lechner
Refactor code to set the read address in a separate function. This code is already duplicated twice and we will need to use it a third time in a later commit. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-7-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: audit included headersDavid Lechner
Drop linux/iio/sysfs.h since it is unused and replace linux/kernel.h with more explicit headers. There are a couple of other headers added weren't covered by kernel.h, like linux/gpio/consumer.h that are added since the module makes use of those APIs as well. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-6-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: use BITS_TO_BYTES() macroDavid Lechner
Use the BITS_TO_BYTES() macro instead of dividing by 8 to convert bits to bytes. This makes it more obvious what unit conversion is taking place. In one instance, we also avoid the temporary assignment to a variable as it was confusing that reg_size was being used with two different units (bits and bytes). scan_type is factored out to reduce line wrapping. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-5-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: use sizeof() in ALIGN()David Lechner
Use sizeof() instead of hardcoding the size of the timestamp in the ALIGN() macro. This makes it a bit more obvious what the intention of the code is. Suggested-by: Andy Shevchenko <andriy.shevchenko@intel.com> Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-4-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: use u8 instead of uint8_tDavid Lechner
Replace uint8_t with u8 in the ad_sigma_delta driver. Technically, uint8_t comes from the C standard library, while u8 is a Linux kernel type. Since we don't use the C standard library in the kernel, we should use the kernel types instead. There is also one instance where int64_t is replaced with s64. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-3-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: sort includesDavid Lechner
Sort includes in alphabetical order and fix grouping before we add more. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-2-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-07-13iio: adc: ad_sigma_delta: don't overallocate scan bufferDavid Lechner
Fix overallocating the size of the scan buffer by converting bits to bytes. The size is meant to be in bytes, so scanbits needs to be divided by 8. Signed-off-by: David Lechner <dlechner@baylibre.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250701-iio-adc-ad7173-add-spi-offload-support-v3-1-42abb83e3dac@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-04-22iio: adc: ad_sigma_delta: Fix use of uninitialized status_posPurva Yeshi
Fix Smatch-detected issue: drivers/iio/adc/ad_sigma_delta.c:604 ad_sd_trigger_handler() error: uninitialized symbol 'status_pos'. The variable `status_pos` was only initialized in specific switch cases (1, 2, 3, 4), which could leave it uninitialized if `reg_size` had an unexpected value. Fix by adding a default case to the switch block to catch unexpected values of `reg_size`. Use `dev_err_ratelimited()` for error logging and `goto irq_handled` instead of returning early. Signed-off-by: Purva Yeshi <purvayeshi550@gmail.com> Link: https://patch.msgid.link/20250410170408.8585-1-purvayeshi550@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-03-11iio: adc: ad_sigma_delta: Add error checking for ad_sigma_delta_set_channel()Uwe Kleine-König
All other calls to ad_sigma_delta_set_channel() in ad_sigma_delta.c check the return value afterwards. Do it for all calls. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/20250303114659.1672695-16-u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-03-11iio: adc: ad_sigma_delta: Disable channel after calibrationUwe Kleine-König
The function ad_sd_calibrate() enables the channel to calibrate at function entry but doesn't disable it on exit. This is problematic because if two (or more) channels are calibrated in a row, the second calibration isn't executed as intended as the first (still enabled) channel is recalibrated and after the first irq (i.e. when the calibration of the first channel completed) the calibration is aborted. This currently affects ad7173 only, as the other drivers using ad_sd_calibrate() never have more than one channel enabled at a time. To fix this, disable the calibrated channel after calibration. Fixes: 031bdc8aee01 ("iio: adc: ad7173: add calibration support") Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/20250303114659.1672695-11-u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-03-04iio: adc: ad_sigma_delta: Switch to sparse friendly ↵Jonathan Cameron
iio_device_claim/release_direct() These new functions allow sparse to find failures to release direct mode reducing chances of bugs over the claim_direct_mode() functions that are deprecated. This is a complex function with a lot more than the release of direct mode to unwind on error. As such no attempt made to factor out the inner code. Cc: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Reviewed-by: Nuno Sá <nuno.sa@analog.com> Link: https://patch.msgid.link/20250217141630.897334-21-jic23@kernel.org Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2025-02-03iio: adc: ad7173: move fwnode_irq_get_byname() call siteDavid Lechner
Move the call to fwnode_irq_get_byname() from the driver-specific ad7173_fw_parse_device_config() to the shared ad_sd_init() function. The main reason for this is that we want struct ad_sigma_delta_info to be static const data that describes the actual ADC chip, not the application-specific configuration or any runtime state. Previously, this struct was being used to pass the IRQ number to the shared ad_sd_init() function. Now, this is replaced by a boolean flag that is set at compile time and the ad_sd_init() function handles looking up the IRQ number instead. This also has the added benefit that if any other drivers need to make use of this in the future, they just have to set the flag and the shared code will take care of the rest rather than duplicating the code in each driver. Signed-off-by: David Lechner <dlechner@baylibre.com> Link: https://patch.msgid.link/20250113-iio-adc-ad7313-fix-non-const-info-struct-v4-1-b63be3ecac4a@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-28iio: adc: ad_sigma_delta: Use `unsigned int` instead of plain `unsigned`Uwe Kleine-König
This fixes a checkpatch warning: WARNING: Prefer 'unsigned int' to bare use of 'unsigned' #70: FILE: drivers/iio/adc/ad_sigma_delta.c:253: + unsigned status_reg; Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/20241218114809.1378063-2-u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-11iio: adc: ad_sigma_delta: Check for previous ready signalsUwe Kleine-König
It can happen if a previous conversion was aborted the ADC pulls down the R̅D̅Y̅ line but the event wasn't handled before. In that case enabling the irq might immediately fire (depending on the irq controller capabilities) and even with a rdy-gpio isn't identified as an unrelated one. To cure that problem check for a pending event before the measurement is started and clear it if needed. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/3ec6b61fb1e527e935133dc56f589aab4b2094a3.1733504533.git.u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-11iio: adc: ad_sigma_delta: Store information about reset sequence lengthUwe Kleine-König
The various chips can be reset using a sequence of SPI transfers with MOSI = 1. The length of such a sequence varies from chip to chip. Store that length in struct ad_sigma_delta_info and replace the respective parameter to ad_sd_reset() with it. Note the ad7192 used to pass 48 as length but the documentation specifies 40 as the required length. Assuming the latter is right. (Using a too long sequence doesn't hurt apart from using a longer spi transfer than necessary, so this is no relevant fix.) The motivation for storing this information is that this is useful to clear a pending R̅D̅Y̅ signal in the next change. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/9750db62fce638bf140ff48172c23bff7f785e5b.1733504533.git.u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-11iio: adc: ad_sigma_delta: Fix a race conditionUwe Kleine-König
The ad_sigma_delta driver helper uses irq_disable_nosync(). With that one it is possible that the irq handler still runs after the irq_disable_nosync() function call returns. Also to properly synchronize irq disabling in the different threads proper locking is needed and because it's unclear if the irq handler's irq_disable_nosync() call comes first or the one in the enabler's error path, all code locations that disable the irq must check for .irq_dis first to ensure there is exactly one disable call per enable call. So add a spinlock to the struct ad_sigma_delta and use it to synchronize irq enabling and disabling. Also only act in the irq handler if the irq is still enabled. Fixes: af3008485ea0 ("iio:adc: Add common code for ADI Sigma Delta devices") Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/9e6def47e2e773e0e15b7a2c29d22629b53d91b1.1733504533.git.u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-11iio: adc: ad_sigma_delta: Handle CS assertion as intended in ↵Uwe Kleine-König
ad_sd_read_reg_raw() When struct ad_sigma_delta::keep_cs_asserted was introduced only register writing was adapted to honor this new flag. Also respect it when reading a register. Fixes: df1d80aee963 ("iio: ad_sigma_delta: Properly handle SPI bus locking vs CS assertion") Reviewed-by: Trevor Gamblin <tgamblin@baylibre.com> Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/8d76b4ea4a4363b269886c71193b840821c724ea.1733504533.git.u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-11iio: adc: ad_sigma_delta: Add support for reading irq status using a GPIOUwe Kleine-König
Some of the ADCs by Analog signal their irq condition on the MISO line. So typically that line is connected to an SPI controller and a GPIO. The GPIO is used as input and the respective interrupt is enabled when the last SPI transfer is completed. Depending on the GPIO controller the toggling MISO line might make the interrupt pending even while it's masked. In that case the irq handler is called immediately after irq_enable() and so before the device actually pulls that line low which results in non-sense values being reported to the upper layers. The only way to find out if the line was actually pulled low is to read the GPIO. (There is a flag in AD7124's status register that also signals if an interrupt was asserted, but reading that register toggles the MISO line and so might trigger another spurious interrupt.) Add the possibility to specify an interrupt GPIO in the machine description in addition to the plain interrupt. This GPIO is used then to check if the irq line is actually active in the irq handler. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com> Link: https://patch.msgid.link/5be9a4cc4dc600ec384c88db01dd661a21506b9c.1733504533.git.u.kleine-koenig@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-12-02module: Convert symbol namespace to string literalPeter Zijlstra
Clean up the existing export namespace code along the same lines of commit 33def8498fdd ("treewide: Convert macro and uses of __section(foo) to __section("foo")") and for the same reason, it is not desired for the namespace argument to be a macro expansion itself. Scripted using git grep -l -e MODULE_IMPORT_NS -e EXPORT_SYMBOL_NS | while read file; do awk -i inplace ' /^#define EXPORT_SYMBOL_NS/ { gsub(/__stringify\(ns\)/, "ns"); print; next; } /^#define MODULE_IMPORT_NS/ { gsub(/__stringify\(ns\)/, "ns"); print; next; } /MODULE_IMPORT_NS/ { $0 = gensub(/MODULE_IMPORT_NS\(([^)]*)\)/, "MODULE_IMPORT_NS(\"\\1\")", "g"); } /EXPORT_SYMBOL_NS/ { if ($0 ~ /(EXPORT_SYMBOL_NS[^(]*)\(([^,]+),/) { if ($0 !~ /(EXPORT_SYMBOL_NS[^(]*)\(([^,]+), ([^)]+)\)/ && $0 !~ /(EXPORT_SYMBOL_NS[^(]*)\(\)/ && $0 !~ /^my/) { getline line; gsub(/[[:space:]]*\\$/, ""); gsub(/[[:space:]]/, "", line); $0 = $0 " " line; } $0 = gensub(/(EXPORT_SYMBOL_NS[^(]*)\(([^,]+), ([^)]+)\)/, "\\1(\\2, \"\\3\")", "g"); } } { print }' $file; done Requested-by: Masahiro Yamada <masahiroy@kernel.org> Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org> Link: https://mail.google.com/mail/u/2/#inbox/FMfcgzQXKWgMmjdFwwdsfgxzKpVHWPlc Acked-by: Greg KH <gregkh@linuxfoundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2024-10-12Merge tag 'v6.12-rc2' into test2Jonathan Cameron
Linux 6.12-rc2 Resolved movement of asm/unaligned.h to linux/unaligned.h
2024-10-05iio: adc: Fix typos in comments across various filesYu Jiaoliang
This commit fixes several typographical errors in comments within the drivers/iio/adc directory. No functional changes are made. Detected using codespell. Signed-off-by: Yu Jiaoliang <yujiaoliang@vivo.com> Link: https://patch.msgid.link/20240926034411.3482986-1-yujiaoliang@vivo.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-10-02move asm/unaligned.h to linux/unaligned.hAl Viro
asm/unaligned.h is always an include of asm-generic/unaligned.h; might as well move that thing to linux/unaligned.h and include that - there's nothing arch-specific in that header. auto-generated by the following: for i in `git grep -l -w asm/unaligned.h`; do sed -i -e "s/asm\/unaligned.h/linux\/unaligned.h/" $i done for i in `git grep -l -w asm-generic/unaligned.h`; do sed -i -e "s/asm-generic\/unaligned.h/linux\/unaligned.h/" $i done git mv include/asm-generic/unaligned.h include/linux/unaligned.h git mv tools/include/asm-generic/unaligned.h tools/include/linux/unaligned.h sed -i -e "/unaligned.h/d" include/asm-generic/Kbuild sed -i -e "s/__ASM_GENERIC/__LINUX/" include/linux/unaligned.h tools/include/linux/unaligned.h
2024-09-09Merge 6.11-rc7 into char-misc-nextGreg Kroah-Hartman
We need the char-misc fixes in here as well. Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-08-06iio: adc: ad_sigma_delta: fix irq_flags on irq requestNuno Sa
With commit 7b0c9f8fa3d2 ("iio: adc: ad_sigma_delta: Add optional irq selection"), we can get the irq line from struct ad_sigma_delta_info instead of the spi device. However, in devm_ad_sd_probe_trigger(), when getting the irq_flags with irq_get_trigger_type() we are still using the spi device irq instead of the one used for devm_request_irq(). Fixes: 7b0c9f8fa3d2 ("iio: adc: ad_sigma_delta: Add optional irq selection") Signed-off-by: Nuno Sa <nuno.sa@analog.com> Link: https://patch.msgid.link/20240806-dev-fix-ad-sigma-delta-v1-1-aa25b173c063@analog.com Cc: <stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-07-29iio: adc: ad_sigma_delta: use new '.masklength' accessorsNuno Sa
Make use of iio_get_masklength) and iio_for_each_active_channel() to access '.masklength' so it can be annotated as __private when there are no more direct users of it. Signed-off-by: Nuno Sa <nuno.sa@analog.com> Reviewed-by: Alexandru Ardelean <aardelean@baylibre.com> Link: https://patch.msgid.link/20240702-dev-iio-masklength-private-v1-17-98193bf536a6@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-06-25iio: adc: ad_sigma_delta: add disable_one callbackDumitru Ceclan
Sigma delta ADCs with a sequencer need to disable the previously enabled channel when reading using ad_sigma_delta_single_conversion(). This was done manually in drivers for devices with sequencers. This patch implements handling of single channel disabling after a single conversion. Reviewed-by: Nuno Sa <nuno.sa@analog.com> Signed-off-by: Dumitru Ceclan <dumitru.ceclan@analog.com> Reviewed-by: David Lechner <dlechner@baylibre.com> Link: https://patch.msgid.link/20240607-ad4111-v7-3-97e3855900a0@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-04-29iio: adc: ad_sigma_delta: use 'time_left' variable with ↵Wolfram Sang
wait_for_completion_timeout() There is a confusing pattern in the kernel to use a variable named 'timeout' to store the result of wait_for_completion_timeout() causing patterns like: timeout = wait_for_completion_timeout(...) if (!timeout) return -ETIMEDOUT; with all kinds of permutations. Use 'time_left' as a variable to make the code self explaining. Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Reviewed-by: Nuno Sa <nuno.sa@analog.com> Link: https://lore.kernel.org/r/20240429113313.68359-2-wsa+renesas@sang-engineering.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-03-25iio: adc: ad_sigma_delta: Add optional irq selectionDumitru Ceclan
Add optional irq_num attribute to ad_sigma_delta_info structure for selecting the used interrupt line for ADC's conversion completion. Signed-off-by: Dumitru Ceclan <mitrutzceclan@gmail.com> Reviewed-by: Nuno Sa <nuno.sa@analog.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Link: https://lore.kernel.org/r/20240228110622.25114-2-mitrutzceclan@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-03-21Merge tag 'char-misc-6.9-rc1' of ↵Linus Torvalds
git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/char-misc Pull char/misc and other driver subsystem updates from Greg KH: "Here is the big set of char/misc and a number of other driver subsystem updates for 6.9-rc1. Included in here are: - IIO driver updates, loads of new ones and evolution of existing ones - coresight driver updates - const cleanups for many driver subsystems - speakup driver additions - platform remove callback void cleanups - mei driver updates - mhi driver updates - cdx driver updates for MSI interrupt handling - nvmem driver updates - other smaller driver updates and cleanups, full details in the shortlog All of these have been in linux-next for a long time with no reported issue, other than a build warning for the speakup driver" The build warning hits clang and is a gcc (and C23) extension, and is fixed up in the merge. Link: https://lore.kernel.org/all/20240321134831.GA2762840@dev-arch.thelio-3990X/ * tag 'char-misc-6.9-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/char-misc: (279 commits) binder: remove redundant variable page_addr uio_dmem_genirq: UIO_MEM_DMA_COHERENT conversion uio_pruss: UIO_MEM_DMA_COHERENT conversion cnic,bnx2,bnx2x: use UIO_MEM_DMA_COHERENT uio: introduce UIO_MEM_DMA_COHERENT type cdx: add MSI support for CDX bus pps: use cflags-y instead of EXTRA_CFLAGS speakup: Add /dev/synthu device speakup: Fix 8bit characters from direct synth parport: sunbpp: Convert to platform remove callback returning void parport: amiga: Convert to platform remove callback returning void char: xillybus: Convert to platform remove callback returning void vmw_balloon: change maintainership MAINTAINERS: change the maintainer for hpilo driver char: xilinx_hwicap: Fix NULL vs IS_ERR() bug hpet: remove hpets::hp_clocksource platform: goldfish: move the separate 'default' propery for CONFIG_GOLDFISH char: xilinx_hwicap: drop casting to void in dev_set_drvdata greybus: move is_gb_* functions out of greybus.h greybus: Remove usage of the deprecated ida_simple_xx() API ...
2024-02-17iio: adc: ad_sigma_delta: allow overwriting the IRQ flagsNuno Sa
Make sure we can specify the IRQ trigger type from firmware and drivers won't ignore it. In fact, this how it should be done but since someone might be already depending on the driver to hardcode the trigger type (and not specifying it in firmware), let's do it like this so there's no possible breakage. Signed-off-by: Nuno Sa <nuno.sa@analog.com> Link: https://lore.kernel.org/r/20240117-dev_sigma_delta_no_irq_flags-v1-2-db39261592cf@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-02-08iio: adc: ad_sigma_delta: Follow renaming of SPI "master" to "controller"Uwe Kleine-König
In commit 8caab75fd2c2 ("spi: Generalize SPI "master" to "controller"") some functions and struct members were renamed. To not break all drivers compatibility macros were provided. To be able to remove these compatibility macros push the renaming into this driver. Acked-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Acked-by: Nuno Sa <nuno.sa@analog.com> Link: https://lore.kernel.org/r/de866d09c80c89816df62602ba4ba8ba30e9971f.1707324794.git.u.kleine-koenig@pengutronix.de Signed-off-by: Mark Brown <broonie@kernel.org>
2023-05-20iio: adc: ad_sigma_delta: Fix IRQ issue by setting IRQ_DISABLE_UNLAZY flagMasahiro Honda
The Sigma-Delta ADCs supported by this driver can use SDO as an interrupt line to indicate the completion of a conversion. However, some devices cannot properly detect the completion of a conversion by an interrupt. This is for the reason mentioned in the following commit. commit e9849777d0e2 ("genirq: Add flag to force mask in disable_irq[_nosync]()") A read operation is performed by an extra interrupt before the completion of a conversion. At this time, the value read from the ADC data register is the same as the previous conversion result. This patch fixes the issue by setting IRQ_DISABLE_UNLAZY flag. Fixes: 0c6ef985a1fd ("iio: adc: ad7791: fix IRQ flags") Fixes: 1a913270e57a ("iio: adc: ad7793: Fix IRQ flag") Fixes: e081102f3077 ("iio: adc: ad7780: Fix IRQ flag") Fixes: 89a86da5cb8e ("iio: adc: ad7192: Add IRQ flag") Fixes: 79ef91493f54 ("iio: adc: ad7124: Set IRQ type to falling") Signed-off-by: Masahiro Honda <honda@mechatrax.com> Link: https://lore.kernel.org/r/20230518110816.248-1-honda@mechatrax.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2022-11-23iio: adc: ad_sigma_delta: do not use internal iio_dev lockNuno Sá
Drop 'mlock' usage by making use of iio_device_claim_direct_mode(). This change actually makes sure we cannot do a single conversion while buffering is enable. Note there was a potential race in the previous code since we were only acquiring the lock after checking if the bus is enabled. Fixes: af3008485ea0 ("iio:adc: Add common code for ADI Sigma Delta devices") Signed-off-by: Nuno Sá <nuno.sa@analog.com> Reviewed-by: Miquel Raynal <miquel.raynal@bootlin.com> Cc: <Stable@vger.kernel.org> #No rush as race is very old. Link: https://lore.kernel.org/r/20220920112821.975359-2-nuno.sa@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2022-04-04iio: adc: ad_sigma_delta: Add sequencer supportLars-Peter Clausen
Some sigma-delta chips support sampling of multiple channels in continuous mode. When the operating with more than one channel enabled, the channel sequencer cycles through the enabled channels in sequential order, from first channel to the last one. If a channel is disabled, it is skipped by the sequencer. If more than one channel is used in continuous mode, instruct the device to append the status to the SPI transfer (1 extra byte) every time we receive a sample. All sigma-delta chips possessing a sampling sequencer have this ability. Inside the status register there will be the number of the converted channel. In this way, even if the CPU won't keep up with the sampling rate, it won't send to userspace wrong channel samples. When multiple channels are enabled in continuous mode, the device needs to perform a measurement on all slots before we can push to userspace the sample. If, during sequencing and data reading, a channel measurement is lost, a desync occurred. In this case, ad_sigma_delta drops the incomplete sample and waits for the device to send the measurement on the first active slot. Co-developed-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Link: https://lore.kernel.org/r/20220322105029.86389-5-alexandru.tachici@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2022-02-18iio:adc:ad_sigma_delta: Move exports into IIO_AD_SIGMA_DELTA namespaceJonathan Cameron
In order to avoid unnecessary pollution of the global symbol namespace move the core/library functions into a specific namespace and import that into the various specific device drivers that use them. For more information see https://lwn.net/Articles/760045/ Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Cc: Renato Lui Geh <renatogeh@gmail.com> Cc: Michael Hennerich <Michael.Hennerich@analog.com> Cc: Lars-Peter Clausen <lars@metafoo.de> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Link: https://lore.kernel.org/r/20220130205701.334592-2-jic23@kernel.org
2021-11-17iio: ad_sigma_delta: Remove no-op trigger opsLars-Peter Clausen
The IIO core handles a trigger ops with all NULL callbacks the same as if the trigger ops itself was NULL. Remove the empty trigger ops from the interrupt trigger driver to slightly reduce the boilerplate code. Object size of the driver module is also slightly reduced. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Link: https://lore.kernel.org/r/20211031142130.20791-3-lars@metafoo.de Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2021-06-13iio: adc: ad_sigma_delta: remove ad_sd_{setup,cleanup}_buffer_and_trigger()Alexandru Ardelean
Since all AD Sigma-Delta drivers now use the devm_ad_sd_setup_buffer_and_trigger() function, we can remove the old ad_sd_{setup,cleanup}_buffer_and_trigger() functions. This way we can discourage new drivers that use the ad_sigma_delta lib-driver to use these (older functions). Signed-off-by: Alexandru Ardelean <aardelean@deviqon.com> Link: https://lore.kernel.org/r/20210513120752.90074-13-aardelean@deviqon.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2021-06-13iio: adc: ad_sigma_delta: introduct devm_ad_sd_setup_buffer_and_trigger()Alexandru Ardelean
This is a version of ad_sd_setup_buffer_and_trigger() with all underlying functions (that are used) being replaced with their device-managed variants. One thing to take care here is with {devm_}iio_trigger_alloc(), where both functions take a parent-device object as the first parameter. To make sure nothing quirky is happening, the devm_ad_sd_probe_trigger() function is checking that the provided 'dev' reference is the same as the one stored on the 'struct ad_sigma_delta' driver data. Signed-off-by: Alexandru Ardelean <aardelean@deviqon.com> Link: https://lore.kernel.org/r/20210513120752.90074-6-aardelean@deviqon.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2021-05-17iio: core: move @id from struct iio_dev to struct iio_dev_opaqueJonathan Cameron
Continuing from Alexandru Ardelean's introduction of the split between driver modifiable fields and those that should only be set by the core. This could have been done in two steps to make the actual move after introducing iio_device_id() but there seemed limited point to that given how mechanical the majority of the patch is. Includes fixup from Alex for missing mxs-lradc-adc conversion. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Reviewed-by: Alexandru Ardelean <ardeleanalex@gmail.com> Link: https://lore.kernel.org/r/20210426174911.397061-2-jic23@kernel.org
2021-04-07iio:adc:ad_sigma_delta: Use IRQF_NO_AUTOEN rather than request and disableJonathan Cameron
These devices are not able to mask the signal used as a data ready interrupt. As such they previously requested the irq then immediately disabled it. Now we can avoid the potential of a spurious interrupt by avoiding the irq being auto enabled in the first place. I'm not sure how this code could have been called with the irq already disabled, so I believe the conditional would always have been true and have removed it. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Cc: Lars-Peter Clausen <lars@metafoo.de> Cc: Alexandru Ardelean <ardeleanalex@gmail.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Reviewed-by: Lars-Peter Clausen <lars@metafoo.de> Link: https://lore.kernel.org/r/20210402184544.488862-8-jic23@kernel.org
2021-03-25iio: set default trig->dev.parentGwendal Grignou
When allocated with [devm_]iio_trigger_alloc(), set trig device parent to the device the trigger is allocated for by default. It can always be reassigned in the probe routine. Change iio_trigger_alloc() API to add the device pointer to be coherent with devm_iio_trigger_alloc, using similar interface to iio_device_alloc(). Signed-off-by: Gwendal Grignou <gwendal@chromium.org> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Link: https://lore.kernel.org/r/20210309193620.2176163-2-gwendal@chromium.org Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-12-03iio: ad_sigma_delta: Don't put SPI transfer buffer on the stackLars-Peter Clausen
Use a heap allocated memory for the SPI transfer buffer. Using stack memory can corrupt stack memory when using DMA on some systems. This change moves the buffer from the stack of the trigger handler call to the heap of the buffer of the state struct. The size increases takes into account the alignment for the timestamp, which is 8 bytes. The 'data' buffer is split into 'tx_buf' and 'rx_buf', to make a clearer separation of which part of the buffer should be used for TX & RX. Fixes: af3008485ea03 ("iio:adc: Add common code for ADI Sigma Delta devices") Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Link: https://lore.kernel.org/r/20201124123807.19717-1-alexandru.ardelean@analog.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-07-20iio: adc: ad_sigma_delta: Remove unused variable 'ret'Lee Jones
Fixes the following W=1 kernel build warning(s): drivers/iio/adc/ad_sigma_delta.c: In function ‘ad_sd_trigger_handler’: drivers/iio/adc/ad_sigma_delta.c:405:6: warning: variable ‘ret’ set but not used [-Wunused-but-set-variable] 405 | int ret; | ^~~ Cc: Michael Hennerich <Michael.Hennerich@analog.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-06-20iio: Move attach/detach of the poll func to the coreLars-Peter Clausen
All devices using a triggered buffer need to attach and detach the trigger to the device in order to properly work. Instead of doing this in each and every driver by hand move this into the core. At this point in time, all drivers should have been resolved to attach/detach the poll-function in the same order. This patch removes all explicit calls of iio_triggered_buffer_postenable() & iio_triggered_buffer_predisable() in all drivers, since the core handles now the pollfunc attach/detach. The more peculiar change is for the 'at91-sama5d2_adc' driver, since it's not immediately obvious that removing the hooks doesn't break anything. Eugen was able to test on at91-sama5d2-adc driver, sama5d2-xplained board. All seems to be fine. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com> Tested-by: Eugen Hristev <eugen.hristev@microchip.com> #for at91-sama5d2-adc Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-05-03iio: adc: ad_sigma_delta: Use {get,put}_unaligned_be24()Andy Shevchenko
This makes the driver code slightly easier to read. Cc: Lars-Peter Clausen <lars@metafoo.de> Cc: Michael Hennerich <Michael.Hennerich@analog.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Acked-by: Nuno Sá <nuno.sa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2020-01-18iio: adc: ad-sigma-delta: Allow custom IRQ flagsAlexandru Tachici
Before this patch the ad_sigma_delta implementation hardcoded the irq trigger type to low, assuming that all Sigma-Delta ADCs have the same interrupt-type. This patch allows all drivers using the ad_sigma_delta layer to set the irq trigger type to the one specified in the datasheet. Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-09-08iio: adc: ad_sigma_delta: Export ad_sd_calibrateMircea Caprioru
This patch exports the ad_sd_calibrate function in order to be able to call it from outside ad_sigma_delta. There are cases where the option to calibrate one channel at a time is necessary (ex. system calibration for zero scale and full scale). Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>