This patch adds a periodic online check at the same interval the battery
status gets requested.
With this change the driver can detect when the mouse is turned off while
the dongle is still plugged in.
Tested with a Kysona M600 V-HUB Special Edition.
Signed-off-by: Lode Willems <me@lodewillems.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
|
|
Wait for a response to the battery status request to set the device as
online. This prevent wrong power info when the dongle is connected but
the mouse is turned off.
Signed-off-by: Lode Willems <me@lodewillems.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
|
|
Use a workqueue to periodically check the battery status
Signed-off-by: Lode Willems <me@lodewillems.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
|
|
In this initial the battery is only probed once, a following patch will add
periodic checking.
Signed-off-by: Lode Willems <me@lodewillems.com>