summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/export-to-postgresql.py
diff options
context:
space:
mode:
authorGwendal Grignou <gwendal@chromium.org>2019-08-26 16:02:58 -0700
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2019-09-03 18:55:51 +0100
commit22087c850e8e56c5959640260ab3fa974556ef96 (patch)
tree66325168dba55de147129099f34c19b01bee3908 /tools/perf/scripts/python/export-to-postgresql.py
parentb1e18768ef1214c0a8048327918a182cabe09f9d (diff)
iio: cros_ec: set calibscale for 3d MEMS to unit vector
By default, set the calibscale vector to unit vector. When calibrating one axis, the other axis calibrations are sent as well. If left to 0, sensor data from uncalibrated axis are zero'ed out until all axis are calibrated. Fixes: ed1f2e85da79 ("iio: cros_ec: Add calibscale for 3d MEMS ") Signed-off-by: Gwendal Grignou <gwendal@chromium.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'tools/perf/scripts/python/export-to-postgresql.py')
0 files changed, 0 insertions, 0 deletions