Age | Commit message (Collapse) | Author |
|
Add a test case for commit bb4485562f59 ("ASoC: cs-amp-lib: Ignore
empty UEFI calibration entries").
Any entries in the calibration blob that have calTime==0 are empty
entries. So they must not be returned by a lookup.
Signed-off-by: Richard Fitzgerald <rf@opensource.cirrus.com>
Link: https://patch.msgid.link/20240830144819.118362-1-rf@opensource.cirrus.com
Signed-off-by: Mark Brown <broonie@kernel.org>
|
|
For a normal calibration blob the calTarget values must be non-zero and
unique, and the calTime values must be non-zero. Don't rely on
get_random_bytes() to be random enough to guarantee this. Force the
calTarget and calTime values to be valid while retaining randomness
in the values.
Signed-off-by: Richard Fitzgerald <rf@opensource.cirrus.com>
Fixes: 177862317a98 ("ASoC: cs-amp-lib: Add KUnit test for calibration helpers")
Link: https://patch.msgid.link/20240822115725.259568-1-rf@opensource.cirrus.com
Signed-off-by: Mark Brown <broonie@kernel.org>
|
|
Add a KUnit test for the cs-amp-lib library. This has test cases
for cs_amp_get_efi_calibration_data() and cs_amp_write_cal_coeffs().
A KUNIT_STATIC_STUB_REDIRECT() has been added to
cs_amp_get_efi_variable() and cs_amp_write_cal_coeff() so that the
KUnit test can redirect these to test harness functions.
Much of the testing involves invoking the same function with different
parameters, i.e. the number of amps and the amp index within the array.
This uses parameterization rather than looping. The idea is to avoid
looping over configurations within one test case as that has a higher
chance of having a bug that doesn't actually test all the expected cases.
Having the test run exactly one configuration, and then tear-down, is less
prone to accidentally skipped configurations.
Signed-off-by: Richard Fitzgerald <rf@opensource.cirrus.com>
Link: https://msgid.link/r/20240304143705.26362-1-rf@opensource.cirrus.com
Signed-off-by: Mark Brown <broonie@kernel.org>
|