2024-10-24thermal: netlink: Add the commands and the events for the thresholdsDaniel Lezcano
The thresholds exist but there is no notification neither action code related to them yet. These changes implement the netlink for the notifications when the thresholds are crossed, added, deleted or flushed as well as the commands which allows to get the list of the thresholds, flush them, add and delete. Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Link: https://patch.msgid.link/20241022155147.463475-3-daniel.lezcano@linaro.org [ rjw: Use the thermal_zone guard for locking, subject edit ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-10-10thermal: core: Add user thresholds supportDaniel Lezcano
The user thresholds mechanism is a way to have the userspace to tell the thermal framework to send a notification when a temperature limit is crossed. There is no id, no hysteresis, just the temperature and the direction of the limit crossing. That means we can be notified when a threshold is crossed the way up only, or the way down only or both ways. That allows to create hysteresis values if it is needed. A threshold can be added, deleted or flushed. The latter means all thresholds belonging to a thermal zone will be deleted. When a threshold is added: - if the same threshold (temperature and direction) exists, an error is returned - if a threshold is specified with the same temperature but a different direction, the specified direction is added - if there is no threshold with the same temperature then it is created When a threshold is deleted: - if the same threshold (temperature and direction) exists, it is deleted - if a threshold is specified with the same temperature but a different direction, the specified direction is removed - if there is no threshold with the same temperature, then an error is returned When the threshold are flushed: - All thresholds related to a thermal zone are deleted When a threshold is crossed: - the userspace does not need to know which threshold(s) have been crossed, it will be notified with the current temperature and the previous temperature - if multiple thresholds have been crossed between two updates only one notification will be send to the userspace, it is pointless to send a notification per thresholds crossed as the userspace can handle that easily when it has the temperature delta information Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20240923100005.2532430-2-daniel.lezcano@linaro.org [ rjw: Subject edit, use BIT(0) and BIT(1) in symbol definitions ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>