summaryrefslogtreecommitdiff
path: root/drivers/iio/imu/fxos8700_i2c.c
AgeCommit message (Collapse)Author
2023-05-21iio: Switch i2c drivers back to use .probe()Uwe Kleine-König
After commit b8a1a4cd5a98 ("i2c: Provide a temporary .probe_new() call-back type"), all drivers being converted to .probe_new() and then 03c835f498b5 ("i2c: Switch .probe() to not take an id parameter") convert back to (the new) .probe() to be able to eventually drop .probe_new() from struct i2c_driver. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Link: https://lore.kernel.org/r/20230515205048.19561-1-u.kleine-koenig@pengutronix.de Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2022-11-23iio: imu: fxos8700_i2c: Convert to i2c's .probe_new()Uwe Kleine-König
.probe_new() doesn't get the i2c_device_id * parameter, so determine that explicitly in the probe function. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Link: https://lore.kernel.org/r/20221118224540.619276-109-uwe@kleine-koenig.org Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2021-03-25iio: imu: fxos8700: Drop unneeded explicit castingsAndy Shevchenko
In a few places the unnecessary explicit castings are being used. Drop them for good. Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Link: https://lore.kernel.org/r/20210312134538.3759-1-andriy.shevchenko@linux.intel.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-10-22iio: imu: Add support for the FXOS8700 IMURobert Jones
FXOS8700CQ is a small, low-power, 3-axis linear accelerometer and 3-axis magnetometer combined into a single package. The device features a selectable I2C or point-to-point SPI serial interface with 14-bit accelerometer and 16-bit magnetometer ADC resolution along with smart-embedded functions. FXOS8700CQ has dynamically selectable accelerationfull-scale ranges of ±2 g/±4 g/±8 g and a fixed magnetic measurement range of ±1200 μT. Output data rates (ODR) from 1.563 Hz to 800 Hz are selectable by the user for each sensor. Interleaved magnetic and acceleration data is available at ODR rates of up to 400 Hz. FXOS8700CQ is available in a plastic QFN package and it is guaranteed to operate over the extended temperature range of –40 °C to +85 °C. TODO: Trigger and IRQ configuration support Datasheet: http://cache.freescale.com/files/sensors/doc/data_sheet/FXOS8700CQ.pdf Signed-off-by: Robert Jones <rjones@gateworks.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>