diff options
author | Alexey Kardashevskiy <aik@ozlabs.ru> | 2018-09-28 16:45:39 +1000 |
---|---|---|
committer | Michael Ellerman <mpe@ellerman.id.au> | 2018-12-20 22:59:03 +1100 |
commit | bdbf649efe21173cae63b4b71db84176420f9039 (patch) | |
tree | 517abcd7c3beec086aeab2249bae2630a406179f /tools/perf/scripts/python/export-to-postgresql.py | |
parent | 8c6c942d33f2a79439e86f8f406afae40a5bc767 (diff) |
powerpc/powernv/ioda: Allocate indirect TCE levels of cached userspace addresses on demand
The powernv platform maintains 2 TCE tables for VFIO - a hardware TCE
table and a table with userspace addresses; the latter is used for
marking pages dirty when corresponging TCEs are unmapped from
the hardware table.
a68bd1267b72 ("powerpc/powernv/ioda: Allocate indirect TCE levels
on demand") enabled on-demand allocation of the hardware table,
however it missed the other table so it has still been fully allocated
at the boot time. This fixes the issue by allocating a single level,
just like we do for the hardware table.
Fixes: a68bd1267b72 ("powerpc/powernv/ioda: Allocate indirect TCE levels on demand")
Signed-off-by: Alexey Kardashevskiy <aik@ozlabs.ru>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Diffstat (limited to 'tools/perf/scripts/python/export-to-postgresql.py')
0 files changed, 0 insertions, 0 deletions